Fast, Reliable Testing for Foundation Performance
At AE Construction Ltd, we provide Dynamic Load Testing (DLT) services for quick and effective evaluation of pile capacity and driving performance. This non-destructive testing method is ideal for verifying the structural integrity and bearing capacity of driven piles—without the time or setup requirements of static testing.
Dynamic Load Testing involves applying a high-strain impact force to the top of a pile using a hammer (typically the same one used during installation) while sensors measure stress waves traveling through the pile. The results are analyzed to estimate:
Ultimate load capacity
Driving resistance and efficiency
Pile integrity and potential defects
Soil resistance distribution (shaft and toe)
We use advanced PDA (Pile Driving Analyzer) systems to capture high-resolution data in real-time.
DLT is an excellent solution for:
Driven precast concrete piles
Projects requiring quick on-site verification
Confirming load capacity after pile driving
Supplementing or replacing static load tests in fast-paced projects
Quality assurance in high-volume piling works
Post-installation testing for infrastructure, bridges, or high-rises
It is conducted in accordance with international standards like ASTM D4945 and Eurocode 7.
Preparation & Sensor Installation
Strain gauges and accelerometers are attached to the pile head using quick-set epoxy or steel bands.
Impact Loading
A hammer strike is applied (typically from a drop hammer or diesel hammer) to generate a stress wave.
Data Collection via PDA
Sensors measure force and velocity, capturing the pile’s response to the impact.
Signal Matching & Analysis
Specialized software compares actual signals to theoretical models, estimating capacity and detecting defects.
Reporting & Interpretation
We deliver a comprehensive report with graphs, waveforms, and load-settlement relationships—within hours of testing.
✅ Faster and more economical than static tests
✅ Provides immediate feedback on pile performance
✅ Verifies installation quality and driving stresses
✅ Identifies structural defects, necking, or cracking
✅ Helps optimize pile length and driving energy
✅ Reduces over-design and saves material costs
✔ Fully equipped PDA system with real-time data analysis
✔ Experienced field technicians and geotechnical engineers
✔ Coordination with our pile driving team for same-day testing
✔ Interpretation by certified professionals
✔ Reports that are ready for client, consultant, or regulatory submission
Infrastructure projects (bridges, flyovers, expressways)
Marine and offshore foundations
Industrial and high-rise buildings
Telecommunication and transmission towers
Pile testing during trial or production phases
Criteria | Static Load Test | Dynamic Load Test |
---|---|---|
Test Duration | 1–3 days | < 1 hour |
Setup Complexity | High (kentledge/reaction) | Low |
Cost | High | Lower |
Result Accuracy | Direct measurement | Estimated (via model) |
Best for | Critical projects | High-speed project cycles |
We often recommend a combination of both for high-assurance projects.
We offer comprehensive services including pre-cast pile manufacturing, hydraulic static pile driving with 5 powerful machines, and dynamic pile installation with an automatic diesel hammer.